Firmware update
Leuze electronic
MSI 100/200
73
8
Firmware update
Update the firmware of the MSI 100/200 system
with the help of the MSIsafesoft safe config-
uration software.
8.1
Safety notices for the firmware update
The following safety notices must be observed during and after the firmware update:
Validation /
verification
Once the firmware update has concluded, validate and verify the safety application.
WARNING: Non-safe operation
While the firmware update is running, the MSI 100/200 operates in the non-safe mode. Reli-
able detection of the safety demand is not guaranteed while in this operating state.
•
Therefore, make sure that running the firmware update will not lead to any hazardous
situations.
•
Take action to prevent the machine from being started up unintentionally (by, e.g., dis-
connecting the terminals on the output side from the MSI 100/200 system, and discon-
necting the drives from the power supply).
ATTENTION: Module defect
Interrupting the connection between the PC and safety module during the firmware update
can damage the device.
A faulty or incomplete firmware installation can render communication between the PC and
safety module impossible. In this case, the faulty installation cannot be corrected with the
assistance of MSIsafesoft.
•
Do
not
disconnect the USB cable during the update process.
•
Do
not
switch off the safety module during the update process.