Information LH100 V3.6
79
or
key
Here is the list of possible error messages
Error
happens
during
Explanation
ERR 01
PROG
When programming or reading a decoder, a power overload
(short circuit) was detected. The decoder may not be correctly
connected or may be defective.
ERR 02
PROG
When programming or reading a decoder, no decoder
acknowledgement was detected. That could mean that the
decoder is not correctly connected to the programming output
on command station LZ100 (for example the digital locomotive
may not be properly placed on the programming track) or the
decoder is not functioning properly.
ERR 24
DH/MU
The locomotive was not selected or no command to the
locomotive was sent prior to setting up the MU/double header.
ERR 25
DH/MU
One of the locomotives of the MU/double header is being
operated on another Handheld.
ERR 26
DH/MU
One of the locomotives is already part of another MU/double
header.
ERR 27
DH/MU
One of the two locomotives was not at throttle position 0.
Locomotives must be stopped before you can combine them
into a consist.
ERR 30 Command
station
stack
It is not possible to erase locomotive from command station
stack.
ERR 31 Command
station
stack
The Command station stack is full. You must remove a
locomotive address before you can add another address.
ERR 96 Your LH100 is not able to create a data connection over XpressNET.
Check if the connection of your LH100 to XpressNET was correctly made.
The XpressNET wires A and B may have been switched.
The wrong XpressNET address is set. Please note that you have to set an
address supported by the command station in use. Unplug the
handheld and then plug it back in with the 'St' key pressed and the
current addresses will be displayed and can be changed.
ERR 97 There is an error in the data processing in command station LZ100. All
information about speed, direction and extra functions of the locomotives,
as well as the status of turnouts and feedback encoders has been erased.
The most frequent cause of this is an improper power supply to the LZ100.
If this error appears repeatedly, the battery in LZ100 may be dead. This
battery ensures that the data is stored even after the power to the command
station is turned off. Please contact your model railroad dealer or Lenz
Elektronik for replacement.