2. Locate the front system fan 1. Then, disconnect the front system fan 1 cable from the front system fan 1
connector on the system board. See “System board components” on page 30.
3. Press the two tabs of the front system fan 1 towards each other and carefully slide the front system fan
1 out of the chassis simultaneously.
1
1
2
Figure 70. Removing the front system fan 1
4. If you are instructed to return the old front system fan 1, follow all packaging instructions and use any
packaging materials that are supplied to you for shipping.
Installing the front system fan 1
To install the front system fan 1, do the following:
1. Prepare your server and remove the server cover. See “Preparing your server in advance and removing
2. If needed, remove the old front system fan 1. See “Removing the front system fan 1” on page 93.
94
ThinkServer TS450 User Guide and Hardware Maintenance Manual