1. Remove all media from the drives and turn off all attached devices and the server. Then, disconnect all
power cords from electrical outlets and disconnect all cables that are connected to the server.
2. Remove the server cover. See “Removing the server cover” on page 30.
3. Lay the server on its side for easier access to the system board.
4. Locate the memory slots. See “System-board internal connectors” on page 25.
5. Remove any parts that might prevent your access to the memory slots.
Note:
Depending on your server model, you might need to remove the PCI Express x16 card for easier
access to the memory slots. See “Installing or replacing a PCI card” on page 32.
6. If you are installing a new memory module, open the retaining clips of the memory slot into which you
want to install the new memory module.
Figure 12. Opening the retaining clips
If you are replacing an old memory module, open the retaining clips and gently pull the memory module
out of the memory slot.
Figure 13. Removing a memory module
7. Position the new memory module over the memory slot. Make sure that the notch
1
on the memory
module aligns correctly with the key
2
in the memory slot. Press the memory module straight down into
the memory slot until the retaining clips close.
Chapter 6
.
Replacing FRUs
37
Summary of Contents for ThinkServer TS200v 1008
Page 1: ...ThinkServer Hardware Maintenance Manual ThinkServer TS200v Types 0981 0992 1008 and 1010 ...
Page 2: ......
Page 3: ...ThinkServer Hardware Maintenance Manual ThinkServer TS200v Types 0981 0992 1008 and 1010 ...
Page 12: ...6 ThinkServerHardware Maintenance Manual ...
Page 16: ...10 ThinkServerHardware Maintenance Manual ...
Page 28: ...22 ThinkServerHardware Maintenance Manual ...
Page 82: ...76 ThinkServerHardware Maintenance Manual ...
Page 92: ...86 ThinkServerHardware Maintenance Manual ...
Page 102: ...96 ThinkServerHardware Maintenance Manual ...
Page 105: ......
Page 106: ...Part Number Printed in USA 1P P N ...