Error
FRU/Action
The start-up drive is not in the boot sequence in
configuration.
Check the configuration and ensure the start-up drive is
in the boot sequence.
No operating system installed on the boot drive.
Install an operating system on the boot drive.
The boot sector on the start-up drive is corrupted.
The drive must be formatted. Do the following:
1. Attempt to back up the data on the failing hard disk
drive.
2. Using the operating system programs, format the
hard disk drive.
The drive is defective.
Replace the hard disk drive.
Power Supply Problems
If you suspect a power problem, use the following procedures.
Check/Verify
FRU/Action
Check the following for proper installation.
• Power cord
• On/Off switch connector
• On/Off switch power supply connector
• System board power supply connectors
• Microprocessor(s) connection
Reseat connectors
Check the power cord for continuity.
Power cord
Check the power-on switch for continuity.
Power-on switch
Beep symptoms
Beep symptoms are tones or a series of tones separated by pauses (intervals without sound) during POST.
The following tables describes beep symptoms.
Beep Symptom
FRU/Action
2 short beeps
CMOS setting error
Perform the following actions in order.
1. Start the Setup Utility program and press F10 to Save
and exit. See Chapter 8 “Configuring the server” on
page 77.
2. Start the Setup Utility program and press F7 to load
defaults and then press F10 to Save and exit.
3. Perform a Boot block recovery. See “Recovering
from a POST/UEFI update failure” on page 83.
1 long and 2 short beeps
Monitor or video adapter card
error
Perform the following actions in order.
1. Make sure the monitor is properly connected to the
computer.
2. Replace the video adapter card (if present).
3. Replace the system board.
16
ThinkServerHardware Maintenance Manual
Summary of Contents for ThinkServer TS200v 1008
Page 1: ...ThinkServer Hardware Maintenance Manual ThinkServer TS200v Types 0981 0992 1008 and 1010 ...
Page 2: ......
Page 3: ...ThinkServer Hardware Maintenance Manual ThinkServer TS200v Types 0981 0992 1008 and 1010 ...
Page 12: ...6 ThinkServerHardware Maintenance Manual ...
Page 16: ...10 ThinkServerHardware Maintenance Manual ...
Page 28: ...22 ThinkServerHardware Maintenance Manual ...
Page 82: ...76 ThinkServerHardware Maintenance Manual ...
Page 92: ...86 ThinkServerHardware Maintenance Manual ...
Page 102: ...96 ThinkServerHardware Maintenance Manual ...
Page 105: ......
Page 106: ...Part Number Printed in USA 1P P N ...