3. Note the orientation of the cooling shroud and then place it above the server so that the tabs on both
sides of the cooling shroud are aligned with the corresponding holes or gaps in both sides of the
chassis. Then, lower the cooling shroud into the chassis until it snaps into position.
Note:
If necessary, gently press the cooling shroud on both sides so that the tabs on the cooling shroud
completely engage with both sides of the chassis.
Figure 25. Reinstalling the cooling shroud
4. Reinstall the server cover and reconnect cables to the server. For more information, refer to
the server cover and reconnecting cables” on page 142.
Installing or removing a memory module
Note:
The memory modules are extremely sensitive to ESD. Ensure that you read and understand
sensitive devices” on page 56 first and carefully perform the operation.
Memory module installation rules
Your server has 16 memory slots. The following list describes the memory module installation rules.
• Each slot supports 4 GB, 8 GB, 16 GB and 32 GB double data rate 4 registered dual inline memory
modules (DDR4 RDIMMs) with Error Checking and Correcting (ECC) technology.
• Each slot supports 32 GB and 64 GB double data rate 4 load reduction dual inline memory modules
(DDR4 LRDIMMs) with ECC technology.
• Your server supports up to eight memory modules when one microprocessor is installed, or up to 16
memory modules when two microprocessors are installed.
• The minimum system memory is 4 GB (only one microprocessor installed and only one 4 GB RDIMM
installed in the CPU1 DIMMA1 slot).
• The maximum system memory is 1024 GB (two microprocessors installed and one 64 GB LRDIMM
installed in each of the 16 memory slots).
For more information about the memory modules in your specific server model, use the Setup Utility
program. See
“Viewing information in the Setup Utility program” on page 43.
62
ThinkServer RD350G User Guide and Hardware Maintenance Manual
Summary of Contents for ThinkServer RD350G
Page 14: ...xii ThinkServer RD350G User Guide and Hardware Maintenance Manual ...
Page 18: ...4 ThinkServer RD350G User Guide and Hardware Maintenance Manual ...
Page 20: ...6 ThinkServer RD350G User Guide and Hardware Maintenance Manual ...
Page 54: ...40 ThinkServer RD350G User Guide and Hardware Maintenance Manual ...
Page 68: ...54 ThinkServer RD350G User Guide and Hardware Maintenance Manual ...
Page 168: ...154 ThinkServer RD350G User Guide and Hardware Maintenance Manual ...
Page 180: ...166 ThinkServer RD350G User Guide and Hardware Maintenance Manual ...
Page 185: ......
Page 186: ...Lenovo ...