1. Read the safety information in Chapter 2 “Safety information” on page 3 and “Installation guidelines”
on page 67.
2. Turn off the server and peripheral devices and disconnect all power cords.
3. Remove the cover (see “Removing and replacing the cover” on page 72).
4. Align the holes on the PCI riser card and the PCI bracket and install the screw that attaches the PCI
riser-card to the PCI bracket.
1
PCI riser-card bracket
2
Screw
3
PCI riser-card
5. If you need to install an adapter, see “Removing and installing an adapter” on page 82.
6. Install the PCI riser card assembly (see “Removing and installing a PCI riser-card assembly” on page 81).
7. Reconnect the cables for the adapter.
8. Install the cover (see “Removing and replacing the cover” on page 72).
9. Slide the server into the rack.
10. Reconnect the power cords and any cables that you removed.
11. Turn on the peripheral devices and the server.
Removing and installing a remotely installed RAID adapter battery
To remove and install a remotely installed RAID adapter battery, complete the steps in this section.
Removing a remotely installed RAID adapter battery
If a RAID adapter battery is installed remotely on the microprocessor 2 air baffle and you need to replace it,
complete the following steps:
1. Read the safety information in Chapter 2 “Safety information” on page 3 and “Installation guidelines”
on page 67.
2. Turn off the server and peripheral devices and disconnect all power cords.
3. Remove the cover (see “Removing and replacing the cover” on page 72).
4. From the top of the microprocessor 2 air baffle, remove the battery retention clip that holds the battery in
place. Press the release tab toward the front of the server and remove the battery retention clip.
124
ThinkServer RD210 Hardware Maintenance Manual
Summary of Contents for ThinkServer RD210
Page 1: ...ThinkServer RD210 Hardware Maintenance Manual ThinkServer RD210 Types 3795 3796 3818 and 3819 ...
Page 2: ......
Page 3: ...ThinkServer RD210 Hardware Maintenance Manual ThinkServer RD210 Types 3795 3796 3818 and 3819 ...
Page 7: ...Korean Class A warning statement 172 Copyright Lenovo 2005 2010 vii ...
Page 8: ...viii ThinkServer RD210 Hardware Maintenance Manual ...
Page 22: ...14 ThinkServer RD210 Hardware Maintenance Manual ...
Page 26: ...18 ThinkServer RD210 Hardware Maintenance Manual ...
Page 70: ...62 ThinkServer RD210 Hardware Maintenance Manual ...
Page 74: ...66 ThinkServer RD210 Hardware Maintenance Manual ...
Page 142: ...134 ThinkServer RD210 Hardware Maintenance Manual ...
Page 172: ...164 ThinkServer RD210 Hardware Maintenance Manual ...
Page 181: ......
Page 182: ...Part Number 40M2493 Printed in USA 1P P N 40M2493 40M2493 ...