Removing the hot-swap SAS/SATA hard disk drive backplane
To remove the hot-swap SAS/SATA hard disk drive backplane, complete the following steps:
1. Read the safety information in Chapter 2 “Safety information” on page 3 and “Installation guidelines”
on page 67.
2. Turn off the server and peripheral devices and disconnect all power cords.
3. Remove the cover (see “Removing and replacing the cover” on page 72).
4. Pull the hard disk drives out of the server slightly to disengage them from the backplane.
5. Disconnect the power cable from the power backplane.
6. Disconnect the signal cable from the system board.
7. Lift up to remove the backplane from the slots.
8. Push backwards on the backplane until it is clear of the slots.
9. Lift the backplane out of the server.
10. Disconnect the power cable and the signal cable from the disk drive backplane.
1
Backplane tabs
2
Hard disk drive backplane
3
Backplane tabs
4
Backplane bracket slots
11. If you are instructed to return the backplane, follow all packaging instructions, and use any packaging
materials for shipping that are supplied to you.
Installing the hot-swap SAS/SATA hard disk drive backplane
To install the replacement hot-swap SAS/SATA hard disk drive backplane, complete the following steps:
1. Read the safety information in Chapter 2 “Safety information” on page 3 and “Installation guidelines”
on page 67.
2. Connect the power cable and signal cable to the replacement backplane.
108
ThinkServer RD210 Hardware Maintenance Manual
Summary of Contents for ThinkServer RD210
Page 1: ...ThinkServer RD210 Hardware Maintenance Manual ThinkServer RD210 Types 3795 3796 3818 and 3819 ...
Page 2: ......
Page 3: ...ThinkServer RD210 Hardware Maintenance Manual ThinkServer RD210 Types 3795 3796 3818 and 3819 ...
Page 7: ...Korean Class A warning statement 172 Copyright Lenovo 2005 2010 vii ...
Page 8: ...viii ThinkServer RD210 Hardware Maintenance Manual ...
Page 22: ...14 ThinkServer RD210 Hardware Maintenance Manual ...
Page 26: ...18 ThinkServer RD210 Hardware Maintenance Manual ...
Page 70: ...62 ThinkServer RD210 Hardware Maintenance Manual ...
Page 74: ...66 ThinkServer RD210 Hardware Maintenance Manual ...
Page 142: ...134 ThinkServer RD210 Hardware Maintenance Manual ...
Page 172: ...164 ThinkServer RD210 Hardware Maintenance Manual ...
Page 181: ......
Page 182: ...Part Number 40M2493 Printed in USA 1P P N 40M2493 40M2493 ...