• Follow the suggested actions in the order in which they are listed in the Action column until the problem is
solved.
• See Chapter 3 “
Parts listing
” on page 29 to determine which components are consumable, structural, or CRU
parts.
• If an action step is preceded by “(Trained technician only),” that step must be performed only by a trained
technician.
Diagnostic
code
Message
Description
Action
I.2018002
[I.2018002] The device
found at Bus % Device
% Function % could not
be configured due to
resource constraints.
The Vendor ID for the
device is % and the
Device ID is %.
OUT_OF_RESOURCES
(PCI Option ROM).
1. Run the Setup utility (see “Using the Setup
utility” on page 11). Select
Start Options
from the menu and modify the boot
sequence so that you change the load order
of the optional-device ROM code.
2. Run the Setup utility (see “Using the Setup
utility” on page 11) and disable unused
resource to make more space available:
• Select
Start Options
• Select
Planar Ethernet (PXE/DHCP)
to
disable the on-board Ethernet controller
ROM.
• Select
Advanced Functions
, followed by
PCI Bus Control
, and then
PCI ROM
Control Execution
to disable the ROM of
the adapters in the PCI slots.
• Select
Devices and I/O Ports
to disable
any of the on-board devices.
3. If the problem remains, replace the following
components one at a time in the order
shown, restarting the server each time:
• Expansion cards (see “Removing an I/O
expansion card” on page 50 and
“Installing an I/O expansion card” on page
53).
• (Trained technician only) Replace the
system board (see “Removing the system-
board assembly” on page 71 and
“Installing the system-board assembly” on
page 71).
4. See TIP H197144 http://www-947.ibm.com/
support/entry/portal/docdisplay? lndocid=
migr-5084743 for more information.
I.2018003
[I.2018003] A bad option
ROM checksum was
detected for the device
found at Bus % Device
% Function %. The
Vendor ID for the device
is % and the Device ID
is %.
ROM CHECKSUM
ERROR.
1. Run the Setup utility (see “Using the Setup
utility” on page 11). Select
Start Options
from the menu and modify the boot
sequence so that you change the load order
of the optional-device ROM code.
2. Run the Setup utility (see “Using the Setup
utility” on page 11) and disable unused
resource to make more space available:
• Select
Start Options
97
Summary of Contents for BladeCenter HS23 1929
Page 1: ...BladeCenter HS23 Blade Server Problem Determination and Service Guide Machine Types 7875 1929 ...
Page 284: ...268 BladeCenter HS23 Blade ServerProblem Determination and Service Guide ...
Page 289: ...Taiwan BSMI RoHS declaration Appendix B Notices 273 ...
Page 290: ...274 BladeCenter HS23 Blade ServerProblem Determination and Service Guide ...
Page 296: ...280 BladeCenter HS23 Blade ServerProblem Determination and Service Guide ...
Page 297: ......
Page 298: ...Part Number 00KC215 Printed in China 1P P N 00KC215 ...
Page 299: ... 1P00KC215 ...