• See Chapter 3 “
Parts listing
” on page 29 to determine which components are consumable, structural, or CRU
parts.
• If an action step is preceded by “(Trained technician only),” that step must be performed only by a trained
technician.
Error code
Description
Action
201-901-xxx
Failed the memory self test due to a single-bit
error in DIMM
x
OR failed the memory self test
due to a multi-bit error in DIMMs
x
and
y
.
1. If the blade server has stopped responding, turn
off the blade server and pull it out of the bay to
disconnect it from power. See “Turning off the
blade server” on page 7 and “Removing the
blade server from the BladeCenter unit” on page
39.
2. Turn off the blade server and disconnect the
power source. Wait for 45 seconds.
3. Reseat DIMM
x
module” on page 45 and “Installing a memory
module” on page 47.
4. Return the blade server to the blade server bay
and turn on the blade server. See “Installing the
blade server in a BladeCenter unit” on page 39
and “Turning on the blade server” on page 6.
5. Make sure that the DSA Diagnostic code is at
the latest level; then, rerun the test ( “Diagnostic
tools overview” on page 78). The latest code
can be found on the IBM support website at
http://www.ibm.com/ support/entry/portal/
docdisplay? brand=5000008&lndocid=SERV-
DSA.
6. Make sure that the system BIOS firmware is at
the latest level, upgrade if necessary; then, rerun
the test ( “Diagnostic tools overview” on page
78). The BIOS firmware level can be found in the
DSA Diagnostic Event Log within the Firmware/
VPD section for this component. The latest level
firmware for this component can be found on
the IBM support website at http://www-933.ibm.
com/ support/fixcentral/systemx/groupView?
query.productGroup=ibm%2FBladeCenter.
7. If the component failure remains, refer to
Chapter 4 “Removing and replacing blade
server components” on page 37 to replace the
failing DIMMs.
8. Return the blade server to the blade server bay
(see “Installing the blade server in a BladeCenter
unit” on page 39), press F1 during start up and
in the
Setup utility > Resource Utilization
section, click
Available System Memory
to re-
enable all memory; then, rerun the test (see
“Diagnostic tools overview” on page 78).
202-000-xxx
Passed the memory stress test.
N/A
245
Summary of Contents for BladeCenter HS23 1929
Page 1: ...BladeCenter HS23 Blade Server Problem Determination and Service Guide Machine Types 7875 1929 ...
Page 284: ...268 BladeCenter HS23 Blade ServerProblem Determination and Service Guide ...
Page 289: ...Taiwan BSMI RoHS declaration Appendix B Notices 273 ...
Page 290: ...274 BladeCenter HS23 Blade ServerProblem Determination and Service Guide ...
Page 296: ...280 BladeCenter HS23 Blade ServerProblem Determination and Service Guide ...
Page 297: ......
Page 298: ...Part Number 00KC215 Printed in China 1P P N 00KC215 ...
Page 299: ... 1P00KC215 ...