To remove the USB Flash key, complete the following steps.
Step 1. Before you begin, read “Safety” on page iii and “Installation guidelines” on page 37.
Step 2. If the blade server is installed in a BladeCenter unit, remove it (see “Removing the blade server from
the BladeCenter unit” on page 39).
Step 3. Remove the blade server cover (see “Removing the blade server cover” on page 72).
Step 4. If an optional expansion unit is installed, remove the expansion unit (see “Removing an optional
Step 5. Locate the USB Flash key on the system board (see “Blade server connectors” on page 7).
Step 6. Using your fingers, pull the USB Flash key out of the connector.
Step 7. If you are instructed to return the USB Flash key, follow all packaging instructions, and use any
packaging materials for shipping that are supplied to you.
Installing a USB Flash key
Use these instructions to install a USB Flash key in the blade server.
The following illustration shows the installation of the USB Flash key.
To install a USB module, complete the following steps:
Step 1. Locate the USB connector on the blade server (see “Blade server connectors” on page 7).
Step 2. Touch the static-protective package that contains the USB Flash key to any
unpainted
metal
surface on the BladeCenter unit or any
unpainted
metal surface on any other grounded rack
component in the rack in which you are installing the USB module for at least two seconds; then,
remove the USB module from its package.
Step 3. Orient the connector on the USB Flash key with the USB connector on the blade server.
Step 4. Use your fingers to push the USB Flash key into the USB connector on the blade server.
Step 5. Install the cover onto the blade server (see “Installing the blade server cover” on page 73).
Step 6. Install the blade server into the BladeCenter unit (see “Installing the blade server in a BladeCenter
Removing an I/O expansion card
The following sections describe how to remove the following expansion cards:
• vertical-combination-I/O (CIOv)
• horizontal-combination-form-factor (CFFh)
50
BladeCenter HS23 Blade ServerProblem Determination and Service Guide
Summary of Contents for BladeCenter HS23 1929
Page 1: ...BladeCenter HS23 Blade Server Problem Determination and Service Guide Machine Types 7875 1929 ...
Page 284: ...268 BladeCenter HS23 Blade ServerProblem Determination and Service Guide ...
Page 289: ...Taiwan BSMI RoHS declaration Appendix B Notices 273 ...
Page 290: ...274 BladeCenter HS23 Blade ServerProblem Determination and Service Guide ...
Page 296: ...280 BladeCenter HS23 Blade ServerProblem Determination and Service Guide ...
Page 297: ......
Page 298: ...Part Number 00KC215 Printed in China 1P P N 00KC215 ...
Page 299: ... 1P00KC215 ...