• Follow the suggested actions in the order in which they are listed in the Action column until the problem is
solved.
• See Chapter 3 “
Parts listing
” on page 29 to determine which components are consumable, structural, or CRU
parts.
• If an action step is preceded by “(Trained technician only),” that step must be performed only by a trained
technician.
Diagnostic
code
Message
Description
Action
W.58001
[W.58001] The PFA
Threshold limit
(correctable error
logging limit) has been
exceeded on DIMM
number % at address
%. MC5 Status contains
% and MC5 Misc
contains %.
DIMM PFA Threshold
Exceeded.
1. Refer to TIP H21455 for minimum code level.
2. Check the IBM support website for an
applicable retain tip or firmware update that
applies to this memory error.
3. Swap the affected DIMMs (as indicated by
the error LEDs on the system board or the
event logs) to a different memory channel or
microprocessor (see “Installing a memory
module” on page 47 for memory population
sequence).
4. If the error still occurs on the same DIMM,
replace the affected DIMM.
5. (Trained technician only) If the problem
occurs on the same DIMM connector, check
the DIMM connector. If the connector is
damaged, replace the system-board
assembly (see “Removing the system-board
assembly” on page 71 and “Installing the
system-board assembly” on page 71).
6. (Trained technician only) Remove the
affected microprocessor and check the
microprocessor socket pins for any damaged
pins. If a damage is found, replace the
system-board assembly (see “Removing the
system-board assembly” on page 71 and
“Installing the system-board assembly” on
page 71).
7. (Trained technician only) Replace the
affected microprocessor (see “Removing a
microprocessor and heat sink” on page 61
and “Installing a microprocessor and heat
sink” on page 65).
8. (Trained technician only) Replace the system
board (see “Removing the system-board
assembly” on page 71 and “Installing the
system-board assembly” on page 71).
W.58007
[W.58007] Invalid
memory configuration
(Unsupported DIMM
Population) detected.
Please verify the
memory configuration is
valid.
Unsupported DIMM
Population.
1. Reseat the DIMMs and restart the server (see
“Removing a memory module” on page 45
and “Installing a memory module” on page
47).
2. Make sure that the DIMMs are installed in the
proper sequence (see “Installing a memory
module” on page 47).
92
BladeCenter HS23 Blade ServerProblem Determination and Service Guide
Summary of Contents for BladeCenter HS23 1929
Page 1: ...BladeCenter HS23 Blade Server Problem Determination and Service Guide Machine Types 7875 1929 ...
Page 284: ...268 BladeCenter HS23 Blade ServerProblem Determination and Service Guide ...
Page 289: ...Taiwan BSMI RoHS declaration Appendix B Notices 273 ...
Page 290: ...274 BladeCenter HS23 Blade ServerProblem Determination and Service Guide ...
Page 296: ...280 BladeCenter HS23 Blade ServerProblem Determination and Service Guide ...
Page 297: ......
Page 298: ...Part Number 00KC215 Printed in China 1P P N 00KC215 ...
Page 299: ... 1P00KC215 ...