• See Chapter 3 “
Parts listing
” on page 29 to determine which components are consumable, structural, or CRU
parts.
• If an action step is preceded by “(Trained technician only),” that step must be performed only by a trained
technician.
Message
Action
System over recommended 5 V fault.
Informational only.
Note:
If the problem remains, complete the following steps:
1. Reseat the blade server. See “Removing the blade server from the
BladeCenter unit” on page 39 and “Installing the blade server in a
BladeCenter unit” on page 39.
2. Check the function of the shared BladeCenter unit resources. See
“Solving shared BladeCenter resource problems” on page 258.
3. (Trained technician only) Replace the system-board assembly. See
“Removing the system-board assembly” on page 71 and
“Installing the system-board assembly” on page 71.
System under recommended voltage for
+12 V.
Informational only.
Note:
If the problem remains, complete the following steps:
1. Reseat the blade server. See “Removing the blade server from the
BladeCenter unit” on page 39 and “Installing the blade server in a
BladeCenter unit” on page 39.
2. Check the function of the shared BladeCenter unit resources. See
“Solving shared BladeCenter resource problems” on page 258.
3. (Trained technician only) Replace the system-board assembly. See
“Removing the system-board assembly” on page 71 and
“Installing the system-board assembly” on page 71.
System under recommended voltage for
+0.9 V.
Informational only.
Note:
If the problem remains, complete the following steps:
1. Reseat the blade server. See “Removing the blade server from the
BladeCenter unit” on page 39 and “Installing the blade server in a
BladeCenter unit” on page 39.
2. Check the function of the shared BladeCenter unit resources. See
“Solving shared BladeCenter resource problems” on page 258.
3. (Trained technician only) Replace the system-board assembly. See
“Removing the system-board assembly” on page 71 and
“Installing the system-board assembly” on page 71.
197
Summary of Contents for BladeCenter HS23 1929
Page 1: ...BladeCenter HS23 Blade Server Problem Determination and Service Guide Machine Types 7875 1929 ...
Page 284: ...268 BladeCenter HS23 Blade ServerProblem Determination and Service Guide ...
Page 289: ...Taiwan BSMI RoHS declaration Appendix B Notices 273 ...
Page 290: ...274 BladeCenter HS23 Blade ServerProblem Determination and Service Guide ...
Page 296: ...280 BladeCenter HS23 Blade ServerProblem Determination and Service Guide ...
Page 297: ......
Page 298: ...Part Number 00KC215 Printed in China 1P P N 00KC215 ...
Page 299: ... 1P00KC215 ...