• Follow the suggested actions in the order in which they are listed in the Action column until the problem is
solved.
• See Chapter 3 “
Parts listing
” on page 29 to determine which components are consumable, structural, or CRU
parts.
• If an action step is preceded by “(Trained technician only),” that step must be performed only by a trained
technician.
Diagnostic
code
Message
Description
Action
S.2011001
[S.2011001] An
Uncorrected PCIe Error
has Occurred at Bus %
Device % Function %.
The Vendor ID for the
device is % and the
Device ID is %.
PCI SERR Detected.
1. Check the IBM support website for an
applicable retain tip or firmware update that
applies to this error.
2. Reseat the expansion cards (see “Removing
an I/O expansion card” on page 50 and
“Installing an I/O expansion card” on page
53).
3. Replace the following components one at a
time in the order shown, restarting the server
each time:
• Expansion cards (see “Removing an I/O
expansion card” on page 50 and
“Installing an I/O expansion card” on page
53).
• (Trained technician only) Replace the
system board (see “Removing the system-
board assembly” on page 71 and
“Installing the system-board assembly” on
page 71).
S.2018001
[S.2018001] An
Uncorrected PCIe Error
has Occurred at Bus %
Device % Function %.
The Vendor ID for the
device is % and the
Device ID is %.
PCIe Uncorrected Error
Detected.
1. Check the IBM support website for an
applicable retain tip or firmware update that
applies to this error.
2. Reseat the expansion cards (see “Removing
an I/O expansion card” on page 50 and
“Installing an I/O expansion card” on page
53).
3. Replace the following components one at a
time in the order shown, restarting the server
each time:
• Expansion cards (see “Removing an I/O
expansion card” on page 50 and
“Installing an I/O expansion card” on page
53).
• (Trained technician only) Replace the
system board (see “Removing the system-
board assembly” on page 71 and
“Installing the system-board assembly” on
page 71).
96
BladeCenter HS23 Blade ServerProblem Determination and Service Guide
Summary of Contents for BladeCenter HS23 1929
Page 1: ...BladeCenter HS23 Blade Server Problem Determination and Service Guide Machine Types 7875 1929 ...
Page 284: ...268 BladeCenter HS23 Blade ServerProblem Determination and Service Guide ...
Page 289: ...Taiwan BSMI RoHS declaration Appendix B Notices 273 ...
Page 290: ...274 BladeCenter HS23 Blade ServerProblem Determination and Service Guide ...
Page 296: ...280 BladeCenter HS23 Blade ServerProblem Determination and Service Guide ...
Page 297: ......
Page 298: ...Part Number 00KC215 Printed in China 1P P N 00KC215 ...
Page 299: ... 1P00KC215 ...