• Follow the suggested actions in the order in which they are listed in the Action column until the problem is
solved.
• See Chapter 3 “
Parts listing
” on page 29 to determine which components are consumable, structural, or CRU
parts.
• If an action step is preceded by “(Trained technician only),” that step must be performed only by a trained
technician.
Diagnostic
code
Message
Description
Action
S.3030007
[S.3030007] A firmware
fault has been detected
in the UEFI image.
Internal UEFI Firmware
Fault Detected, System
halted.
1. Check the IBM support website for an
applicable retain tip or firmware update that
applies to this error.
2. Recover the server firmware (see
“Recovering from a UEFI update failure” on
page 254).
3. (Trained technician only) Replace the system
board (see “Removing the system-board
assembly” on page 71 and “Installing the
system-board assembly” on page 71).
S.3040007
[S.3040007] A firmware
fault has been detected
in the UEFI image.
Internal UEFI Firmware
Fault Detected, System
halted.
1. Check the IBM support website for an
applicable retain tip or firmware update that
applies to this error.
2. Recover the server firmware (see
“Recovering from a UEFI update failure” on
page 254).
I.3048005
[I.3048005] UEFI has
booted from the backup
flash bank.
Booting Backup UEFI
Image.
Information only. Set SW1-5 to the on position to
allow the server to boot from the backup UEFI
(see “System-board switch” on page 8).
W.3048006
[W.3048006] UEFI has
booted from the backup
flash bank due to an
Automatic Boot
Recovery (ABR) event.
Automated Boot
Recovery, Booting
Backup UEFI Image.
1. Run the Setup utility (see “Using the Setup
utility” on page 11), select Load Default
Settings, and save the settings.
2. Recover the server firmware (see
“Recovering from a UEFI update failure” on
page 254).
3. (Trained technician only) Replace the system
board (see “Removing the system-board
assembly” on page 71 and “Installing the
system-board assembly” on page 71).
S.3050007
[S.3050007] A firmware
fault has been detected
in the UEFI image.
Internal UEFI Firmware
Fault Detected, System
halted.
1. Check the IBM support website for an
applicable retain tip or firmware update that
applies to this error.
2. Recover the server firmware (see
“Recovering from a UEFI update failure” on
page 254).
99
Summary of Contents for BladeCenter HS23 1929
Page 1: ...BladeCenter HS23 Blade Server Problem Determination and Service Guide Machine Types 7875 1929 ...
Page 284: ...268 BladeCenter HS23 Blade ServerProblem Determination and Service Guide ...
Page 289: ...Taiwan BSMI RoHS declaration Appendix B Notices 273 ...
Page 290: ...274 BladeCenter HS23 Blade ServerProblem Determination and Service Guide ...
Page 296: ...280 BladeCenter HS23 Blade ServerProblem Determination and Service Guide ...
Page 297: ......
Page 298: ...Part Number 00KC215 Printed in China 1P P N 00KC215 ...
Page 299: ... 1P00KC215 ...