M Series Installation Guide
revision 7 —
31
•
LNL-1320-2RP Dual Door Control Modules
•
LNL-1320-S2RP Supervised Dual Door Control Module
•
LNL-1380-8RP Reader Interface Module is required
5.4
UL Evaluated Readers and Card Formats
All card readers must be evaluated by UL, must be ULC or cUL Listed, and be Wiegand compatible.
To comply with UL, use only the following compatible card readers with the LNL-3300-M5 ISC:
•
940
•
941
•
970
•
971
•
972
•
973
•
430/435
•
1000/1010
Up to 128-bit format.
5.5
Additional UL Requirements
To comply with UL, the following requirements must be adhered to:
•
Connect the LNL-3300-M5 ISC through Ethernet using a dedicated LAN. For backup (dual signal line
transmission), connect the secondary path through a dedicated LAN.
•
A clearly marked redundant system with the same configuration as the primary machine must be
available as a backup.
•
In the event of a primary power loss, an electronic access control system operating on commercial
power must be provided with a capacity of 7 Ah to 12 Ah to support a full load for a period of 30
minutes (Class II).
•
Front and rear tampers must be used. If the enclosure is tampered, a visual and/or audible alarm must
annunciate.
•
When using the LNL-3300-M5 ISC with an M-5 UTC F&S PS/C-6 power supply and an LNL-1320-
2RP Dual Door Control Module or LNL-1380-8RP Reader Interface Module, the card reader outputs
must be rated at a minimum of 12.7 VDC at 150 mA per output.
•
The LNL-3300-M5 ISC must be used with a compatible UL Listed power supply. For more
information, refer to
on page 29. Refer to the instructions provided with
the power supply for installation requirements. The power supply's AC power fail contacts must be
connected to the LNL-3300-M5 ISC as shown in For more information, refer to
Tamper, and Power Fault Input Wiring
on page 46. Grounding must be done in accordance with Article
250 of the National Electrical Code.
•
The LNL-3300-M5 ISC must be mounted inside the secured area.
Summary of Contents for LNL-3300-M5
Page 1: ...7 3 M Series Installation Guide...
Page 4: ......
Page 9: ...HARDWARE INSTALLATION GUIDELINES...
Page 10: ......
Page 33: ...LNL 3300 M5 INTELLIGENT SYSTEM CONTROLLER...
Page 34: ......
Page 54: ...LNL 3300 M5 Intelligent System Controller 54 revision 7...
Page 55: ...LNL 1100 20DI INPUT CONTROL MODULE...
Page 56: ......
Page 65: ...LNL 1200 16DO OUTPUT CONTROL MODULE...
Page 66: ......
Page 75: ...LNL 1200 16DOR OUTPUT CONTROL MODULE...
Page 76: ......
Page 86: ...LNL 1200 16DOR Output Control Module 86 revision 7...
Page 87: ...LNL 1320 2RP DUAL DOOR CONTROL MODULE...
Page 88: ......
Page 108: ...LNL 1320 2RP Dual Door Control Module 108 revision 7...
Page 109: ...LNL 1320 S2RP DUAL DOOR CONTROL MODULE...
Page 110: ......
Page 131: ...LNL 1340 M2K FOUR READER INTERFACE MODULE...
Page 132: ......
Page 155: ...LNL 1380 8RP READER INTERFACE MODULE...
Page 156: ......
Page 170: ...LNL 1380 8RP Reader Interface Module 170 revision 7...
Page 171: ...LNL 8000 MCOM RS 485INTERFACE MODULE...
Page 172: ......
Page 178: ...LNL 8000 MCOM RS 485 Interface Module 178 revision 7...