Group 5
Transport/Start up
Page 37
Release R1.03e
LEIBINGER JET3
The signal type which should be used as encoder source has to be
set in the software of the JET3 under
Settings
X
Basic Settings
X
Encoder Interface.
You will find a circuit diagram of the interface in the appendix of this
manual!
5.4.3.2 Mechanical installation
For the mechanical installation of the shaft encoder you have to
pay attention in any case that the encoder is protected against axial
and radial strain during the mounting and the continuous operation.
For this a rubber gaiter or a plastic coupling is used.
If the conditions allow it, the shaft encoder can be also adapted to a production line
with a friction wheel.
Attention – Risks of injury!
The shaft encoder has to be installed or mounted that no risks of
injury can occur!
5.4.4 Interface X4 (Inputs)
19 inputs for special functions are available whereof the connections of 6 inputs
can be freely selected.
Pin Designation
Pin Designation
1 +Reset
Counter
14
+24V
(1)
2
+Increment Counter
15 GND Reset Counter /
Increment Counter
3
+Jobselect 0
16 +Jobselect 1
4
+Jobselect 2
17 +Jobselect 3
5
+Jobselect 4
18 +Jobselect 5
6
+Jobselect 6
19 +Jobselect 7
7
+Jobselect 8
20 +Jobselect 9
8
GND Jobselect 0-9
21 GND Input 0-5
9
+Input 0
22 +Input 1
10 +Input 2
23 +Input 3
11 +Input 4
24 +Input 5
12 +Power ON
25 GND Power On
13 GND
24V
Plug assignment: