Group 7
Data/Programming
Page 90
Release R1.03e
LEIBINGER JET3
7.4.1 I/O Test (Signaltest)
With the option
<I/O Test>
(2) the menu „I/O-Signals (3)“ is displayed. The menu
shows the states of the inputs and outputs of the device.
Figure 46
5
I/O-Signal test
1 – Button <ServiceFunctions>
4 – Status display <I/O active/inactive>
2 – Option <I/O-Test>
5 – Button <Close>
3 – Menu <I/O-Signals>
The
button
<Close>
(5) ends the menu.
1
2
5
4
3