Group 7
Data/Programming
Page 102
Release R1.03e
LEIBINGER JET3
7.4.4 Special functions and tools
Under the register card
<Special Functions/Tools>
the following functions are
available:
Pressureless
Mix only Ink
Constant Bleed
Mix only Solvent
Drain Routine
Ignore error messages and warnings
Fill up Routine
7.4.4.1 Constant bleed
The function constant bleeding is only activated or functional under
the following device conditions:
Ink suction is turned on
Nozzle is closed
Head cover has been detached
By pressing the button
<Constant Bleed>
(1) the constant bleeding is started.
During the process the message
„Constant Bleed“
(2) is displayed. The bleeding can
be canceled any time by pressing on the button
<Stop>
(3). During this process
the visco pump is activated for 3 sec. every minute to ensure a purging of the
pump.
With the button
<Add Solv>
(4) you can add only solvent. This function provides
specially filling operations to bleed e.g. the solvent tube or to set the viscosity of
the ink faster to a lower value.
Attention!
By adding the solvent the ink can be diluted too strong. Therefore