71
User
Manual
for
ELD2
Servo
Pr5.30
Communication band
rate
Setting
value
Baud rate
Setting
value
Baud rate
0 2400bps
4 38400bps
1 4800bps
5 57600bps
2 9600bps
6 115200bps
3 19200bps
Baud rate deviation is 2400~38400bps±5%,
57600~115200bps±2%
Pr5.31
Device No.
Modbus sub-station address number(Slave ID) .
Pr8.02 PR
trigger
(
16bit
,
485 address..0x6002
)
Write 0x01P
,
P section positioning Write
0x020
,
homing
Write 0x021
,
The current location manually set to zero.
Write 0x040
,
e-stop
Read 0x000p
,
means positioning completed, can receive new data .
Read 0x01P
、
0x020
、
0x040 Means still no responding to commands.
Read 0x10P
,
means path is running.
Read 0x200
,
means instructions completed and wait for positioning.
Communication address mapping of Pr-MODE
485 address
Parameter Name
Specification
0x6000
Pr8.00
PR control setup
HEX
0x6002
Pr8.02
PR control register HEX
0x6006 Pr8.06
Positive
software
limit
H
Pulse
0x6007 Pr8.07
Positive
software
limit
L
Pulse
0x6008 Pr8.08
Negative
software
limit
H
Pulse
0x6009 Pr8.09
Negative
software
limit
L
Pulse
0x600a Pr8.10
Homing
mode
HEX
0x600b Pr8.11
Zero
position
H
Pulse
0x600c Pr8.12
Zero
position
L
Pulse
0x600d Pr8.13
Homing
stop
position
H
Pulse
0x600e Pr8.14
Homing
stop
position
L
Pulse
0x600f Pr8.15
High
speed
homing
r/min
0x6010 Pr8.16
Low
speed
homing
r/min
0x6011 Pr8.17
Homing
acceleration
ms/Krpm
0x6012 Pr8.18
Homing
deceleration
ms/Krpm
0x6016
Pr8.22
Position limit e-stop speed
r/min
0x6017 Pr8.23
STP
e-stop
speed
r/min
0x602a
Pr8.42
Command position H
Read only
0x602b
Pr8.43
Command position L
Read only
0x602c
Pr8.44
Motor position H
Read only
0x602d
Pr8.45
Motor position L
Read only
0x602e
Pr8.46
Input IO status
Read only
0x602f
Pr8.47
Output IO status
Read only
Pr9.00~Pr9.07 PR0
parameters
0x6200 Pr9.00
PR0
mode HEX
0x6201
Pr9.01
PR0 position H
Pulse
0x6202
Pr9.02
PR0 position L
Pulse