Interrupt function can be understood as a path's priority. Interrupt valid path, can suspend or drop
current path under the trigger, run the path directly. Similar to the interrupt priority level of functions.
To set it in the path set parameters.
7.3.3 Position limit, JOG and E-stop function.
Relevant parameters
Parameters
Name
Specification
P800
PR Control parameter
Bit1
:
Software limit is valid
P806-P807
Positive limit
Software limit positive position
P808-P809
Negative limit
Software limit negative position
P822
Position limit E-stop time
Acceleration deceleration after position limit
P823
E-stop time
Acceleration deceleration after E-stop
P312
JOG Acceleration time
Unit: ms/1000rpm
P313
JOG Deceleration time
Unit: ms/1000rpm
P604
JOG speed
Unit: rpm
SI
Input terminal
Forced E-stop
STP 22h
Positive JOG
JOG+ 23h
Negative JOG
JOG- 24h
Positive position limit
PL 25h
Negative position limit
NL 26h