55
User
Manual
for
ELD2
Servo
2
PA_312
Acceleration time setup
/
User-specified
millisecond
3
PA_313
Deceleration time setup
/
User-specified
millisecond
4
PA_314
Sigmoid acceleration/deceleration time
setup
/
User-specified
millisecond
5
PA_315
Zero-clamp function selection
/
0
/
6
PA_319
Torque command direction input gain
/
User-specified
0.1V/100%
7
PA_320
Torque setup input reversal
/
User-specified
/
8
PA_321
Speed limit value 1
/
User-specified
R/min
9
PA_400
SI1 input selection
Srv_on
hex:0383
/
10
PA_422
Analog input offset setup
/
User-specified
0.359mv
11
PA_423
Analog input filter
/
User-specified
0.01ms
◆
Wiring Diagram
◆
Operation Steps
1. connect terminal CN1.
2. Enter the power (DC12V to 24V) to control signal (the COM + and COM-).
3. Enter the power to the driver.
4. Confirm the value of the parameters, and write to the EEPROM and turn off/on the power (of the driver)
5. Apply DC voltage between torque command input , VIN+ and VIN-, and gradually increase from 0V to
confirm the motor runs.
6.3 Automatic Control Mode Run
6.3.1 Operation Mode Selection
ELD2
series
Low
‐
voltage
AC
servo
drives
support
the
position,
speed,
torque
three
basic
modes
of
operation,
and
can
switch
freely
between
the
three
basic
modes
of
operation
by
switch
or
modify
parameters.
Table
7.7
Parameter
setup
of
Operation
Mode
Selection
No
Mode
Parameter
Specification
1
Position mode PA_001=20
The position control is performed based on the positional command
(pulse train) from the host controller or the command set in the
servo driver.
2
Velocity mode PA_001=21
The velocity control is performed according to the analog speed
command from the host controller or the speed command set in the
servo driver.
3
Torque mode
PA_001=22
The torque control is performed according to the torque command
specified in the form of analog voltage or the command set in the
servo driver.
4
1st mode:
position mode
2nd mode:
speed mode
PA_001=23
The control mode is switched through external input.
5
1st mode:
position mode
2nd Mode:
torque mode
PA_001=24
The control mode is switched through external input.
6
1st mode:
speed mode
2nd Mode:
PA_001=25
The control mode is switched through external input.