8. CONFIGURATION
78
8.9.3
Displaying DVI-I Information
You can display DVI-I output information in the DVI-I INFORMATION display screen. The
information appears when you select DVI-I INFORMATION on the menu screen. This screen
is only for viewing. You cannot set values in this screen.
●
Display
HOT PLUG
IN / OUT / DIS
IN:
Appears when a device is connected to the LT 450.
OUT:
Appears when a device is not connected to the LT
450.
DIS:
Appears when HOT PLUG is set to OFF using the
procedure described in section 8.9.2, “Configuring the
DVI-I Output.”
HDCP
OK / NG / DISABLE
OK:
Appears when the device connected to the LT 450
supports HDCP.
NG:
Appears when the device connected to the LT 450
does not support HDCP.
DISABLE: Appears when HDCP is set to OFF using the
procedure described in section 8.9.2, “Configuring the
DVI-I Output.”
EDID BASIC
EDID: Extended display identification data
EDID EXTEND
If you select EDID BASIC or EDID EXTEND and press ENTER,
the EDID of the device connected to the LT 450 will be displayed.
You can scroll through the information by pressing
and
to
move the arrow. If DDC is set to OFF in section 8.9.2,
“Configuring the DVI-I Output,” the ENTER key will be disabled
and the EDID that was retrieved previously will appear.
To exit from the EDID display screen, press MENU.
●
Procedure
MENU
→
DVI-I
→
DVI-I INFORMATION
Figure 8-32 DVI-I information display
*