AutoFocus User’s Guide
35
©1989-2018 Lauterbach GmbH
8. Check
Check the version of your PowerTrace I module. Version 6 is required for targets running faster than
200 MHz (
VERSION.HARDWARE2
).
9. Check
Check the preprocessor seen by the TRACE32 software.
VERSION.HARDWARE
shows all detected
hardware.
10. Check
In case of preprocessors with more than one Mictor connector, double-check that the Mictor connectors are
properly connected to your target. For trace port sizes <= 16 bit, TRACE B remains unconnected. For further
information on the correct connection of TRACE A / TRACE B, refer to
Dimensions
.
11. Check
Check the trace port pinout.
Did your target board work with other PowerTrace/Preprocessor combinations? If your target worked with
other PowerTrace/preprocessor combinations, your trace port pinout can be assumed to be correct. This is
not always true for TPAs from other vendors. Lauterbach tools assume that the trace port pinout follows
exactly the trace specification of the used architecture (please refer to
Connector Layout
).
Has to be 06-00 or higher
Detected preprocessor hardware
must show AutoFocus!