AutoFocus User’s Guide
15
©1989-2018 Lauterbach GmbH
Software Installation
TRACE32 PowerView includes debug and trace tool support. An extra software installation is not required,
but valid license keys are required.
Recommendation for the Software Start
1.
Disconnect the debug cable from the target while the target power is off.
2.
Start the TRACE32 software.
3.
Connect the debug cable directly to the target.
-
If there is no appropriate jack on your target, you can also connect the debug cable to the
preprocessor (for ARM/Mipi conform devices only).
-
Alternatively, connect the debug cable to an additional converter PCB, which splits debug and
trace signals. The converter PCB needs to be ordered separately at Lauterbach.
4.
Connect the preprocessor to your target’s trace port by using the flex extension cable delivered
with your preprocessor. For port sizes greater 16 bit, you need to connect port TRACE B as well,
using a second Mictor flex extension (not for LA-7993).
5.
Switch the target power on.
6.
Run your start-up script.
Recommendation for Power Down
1.
Switch off the target power.
2.
Disconnect the debug cable and preprocessor (flex extension cable) from the target.
3.
Shut down the TRACE32 PowerView GUI.
4.
Switch off the TRACE32 hardware.
NOTE: