BATCHING DATA ALARMS
Index
Alarm
Description
0
No alarm
1
Generic alarm
2
Empty formula
3
The quantity set in formula is greater than the maximum weight
4
The weight is greater than the minimum weight set
5
6
7
Out of tolerance
8
The product is not being loaded
9
The product is not being unloaded
10
11
12
Batching STOP
13
Weight error
14
The fall is greater than the quantity to be batched
15
Waits for the confirmation of data reading from PC
CONSUMPTION MANAGEMENT
If in batching constants consumption is enabled (
=
), the batched quantities for each
formula are stored (see section
CONSUMPTION FOR EACH FORMULA
).
CONSUMPTION READING
Selecting
the following information is displayed:
-
total quantity consumed for all formulas (divided by 100);
-
quantity consumed for each formula.
COMMUNICATION INTERFACE
Write the formula number in W2 and send command 2020 to CMDR; read the consumption related
to the formula in R1.
…