- 35 -
(from 0 to 32000; default: 0): in this parameter it is possible to set the fall value for each
formula (only if
= 0) or to display and/or to modify the fall value calculated automatically by
the instrument (only if
is different from 0).
COMMUNICATION INTERFACE
WRITING
READING
Write the formula number in W2.
Write the
value in W1.
Send command 1013 to CMDR.
Write the formula number in W2.
Send command 1012 to CMDR.
Read the
value in R1.
TOLERANCE
(from 0 to maximum weight; default: 0): Adjustable parameter for each formula that defines how
much the batched weight value can deviate from the one set in formula. If the batched weight is
higher or lower than the amount to be batched, for a value greater than the tolerance, the display
shows the
alarm.
Example
: if a SET = 1000 value is set and a TOLERANCE = 100 value is set, the batched weight
must not be lower than 900 or higher than 1100
to allow the instrument to continue the batching
process. By setting 0, the function is disabled.
COMMUNICATION INTERFACE
WRITING
READING
Write the formula number in W2.
Write the
value in W1.
Send command 1017 to CMDR.
Write the formula number in W2.
Send command 1016 to CMDR.
Read the
value in R1.
SLOW
(from 0 to maximum weight; default: 0): single valid value for all the formulas in place of the
preset value. When the weight has reached the SET value minus the value set in this parameter, the
slow batching phase starts by the PRESET contact. If the set value is greater than the weight to
batch, the batching will be in slow phase. By setting 0, the function is disabled.
Example
: if SET = 100 and SLOW = 15, the slow phase begins when the weight reaches 85.
COMMUNICATION INTERFACE
WRITING
READING
Write the value in W1.
Send command 1021 to CMDR.
Send command 1020 to CMDR.
Read the value in R1.