SET-HD100
(E)
5
2-3-2. Rear Panel
2 Fuse
3 Power supply connector
4 Ground terminal
1 POWER switch
a
POWER
switch
Th
is turns the interpolator unit power on and off .
Notes
• Finish all the connections before turning on the power. (See section 3-2 “Connections.”)
• Be sure to always turn off the power before connecting or disconnecting the connection cable. If the
cable is connected or disconnected while the power is on, the sensor light source may be damaged.
b
Fuse
Th
is fuse is used to prevent overcurrent.
Notes
• Be sure to always use the specifi ed fuse
*
. (
*
: Rated voltage 250 V, rated current 15 A)
• Be sure to always turn off the power before replacing the fuse.
c
Power supply connector
Th
is supplies external power.
Connect the AC adaptor (sold separately) or DC +24 V power supply.
Connector
: D-sub 9-pin plug with screw
lock
Input power supply : 5 A (Max. 8 A)
Inrush current
: 14 A or less
Pin Signal
1 +24
V
2 +24
V
3 +24
V
4 +24
V
5 NC
6 GND
7 GND
8 GND
9 GND
d
Ground
terminal
Th
is ground terminal is the same potential as the frame and the ground side of the signal line.
When installing the interpolator unit, connect this terminal and the connected machine with a
ground wire.
Note
Establish a reliable connection between the interpolator unit and ground. If the ground connection is
unstable, proper performance may not be achieved.
Summary of Contents for SET-HD100
Page 10: ...ii J SET HD100 9 外形寸法図 23 9 1 ヘッドユニット スケールユニット 23 9 2 インターポレータユニット 25 ...
Page 25: ... J 15 SET HD100 梱包袋 キャリーケース 接続ケーブル CS03 05 クッション 4 心出し治具 収納 5 接続ケーブル 収納 心出し治具 ...
Page 26: ...16 J SET HD100 キャリーケース バンド ロックする バンドで固定 6 蓋を閉めてロック 収納完了 7 ...
Page 32: ...22 J SET HD100 8 7 接続ケーブル 項目 仕様 コネクタ 本多通信工業製 PCR E68FA 両端 ケーブル長 5 m ...
Page 35: ... J 25 SET HD100 9 2 インターポレータユニット 110 118 210 298 単位 mm ...
Page 36: ...26 J SET HD100 ...
Page 69: ...SET HD100 E 25 9 2 Interpolator Unit 210 110 118 298 Serial No Unit mm ...
Page 70: ...SET HD100 26 E ...
Page 71: ......