7-14
Performing the Measurement
Model 831 Manual
The
OK
response will already be highlighted, so simply
press the
5
(ENTER) key to continue.
Otherwise, highlight
Cancel
and then the
5
to cancel both
the Stop and the Reset operations.
After selecting to Stop the measurement, the Save File
Menu, shown in FIGURE 7-13, will appear to provide a
choice of saving the measured data prior to the reset or not
as described in “Storing the Measurement” on page 7-15.
Resetting When Stopped
If the Model 831 is stopped when the
1
key is pressed, the
Stop Required Menu will not appear, but the Save File Menu
will appear to provide a choice of saving the measured data
prior to the reset or not.
After the reset has been performed, the
7
key will
produce a steady red light to indicate the measurement state
as Stopped, Reset.
Starting a New Measurement
The
9
key (RUN/PAUSE) key must be pressed to start a
new measurement.
Stopping the Measurement
Note that the Model 831 can be
stopped when either running or
paused.
Press the
7
key to suspend the overall measurement,
which will also stop the run clock. Stopping the
measurement with data not yet stored will cause the
7
key
to flash red every 3.2 seconds.
Pressing the
9
key afterwards will continue the overall
measurement which had been stopped. The run clock will
also begin again from the time indicated when the stop had
occurred. This will also cause the
9
to produce a steady
green light.
Summary of Contents for 831
Page 1: ...Model 831 Sound Level Meter Manual...
Page 2: ...I831 01 Rev O Manual Larson Davis Model 831 Manual...
Page 123: ...5 44 Any Level Display Model 831 Manual...
Page 135: ...6 12 Run Modes Without Measurement History Model 831 Manual...
Page 155: ...7 20 Recovery After Improper Shutdown Model 831 Manual...
Page 209: ...11 22 Markers Model 831 Manual...
Page 221: ...12 12 Link to Time History Model 831 Manual FIGURE 12 11 Time History Display...
Page 321: ...16 24 Sound Recording Playback Model 831 Manual...
Page 358: ...Model 831 Manual Displays 18 27 FIGURE 18 42 Measurement Displays FIGURE 18 43 Events Displays...
Page 403: ...20 28 Troubleshooting Model 831 Manual...
Page 413: ...21 10 Calibration When The Model 831 Is Locked Model 831 Manual...
Page 421: ...23 4 File System Model 831 Manual...
Page 501: ...A 64 Vibration Sensitivity Model 831 Manual...
Page 513: ...B 12 Sections 5 6 7 and 9 except 9 3 Model 831 Manual...
Page 525: ...C 12 Community Noise Descriptors Model 831 Manual...