4.
Verify that each Access-T to be downloaded is configured for the
appropriate hardware status and operation mode and has been given
a unique node address. To verify and/or change an Access-T’s
hardware status, operation mode, or node address, do the following:
a. Access-T Series 1500 Units:
check the DIP switch settings on each
module to be downloaded as described under
DIP Switches
in
Chapter 3 of the Access-T Network Access DSU/CSU System Instal-
lation and Operation manual, ACST-0351-xxx.
b. Access-T Series 100, 200 and 400 Units:
check the DIP switch
settings on the rear panel of the unit as described under
DIP
Switches
in Chapter 3 of the Access-T Network Access DSU/CSU
System Installation and Operation manual, ACST-0351-xxx.
c. Access-T 01/02 Units:
check the operation mode and node ad-
dress software configuration as described under
System Configu-
ration
in Chapter 6 of the Access-T Installation and Operation
manual, ACST-0311-xxx.
5.
Using the drop-down menus as described in the Access-T manual, set the
Access-T
SUPV PORT
(Supervisor Port) for the following parameters:
•
Appropriate baud rate-Larscom recommends 9600 baud for
direct connections or 2400 baud for modem connections.
•
1 stop bit.
•
No parity.
•
Either terminal type (TV 925 or VT100).
6.
If modems are used, verify that the modem at the Access-T site is
configured as follows
100/200/400/1500
100-S/100-RDL
Auto answer (
S0 = 1
).
Auto answer (
S0 = 1
).
DTR detect on (
&D2
).
DTR detect on (
&D2
).
Echo off (
E0
).
Echo off (
E1
).
Quiet mode (
Q1
).
Quiet mode (
Q0
).
DCD enabled (
&C1
).
DCD enabled (
&C1
).
Larscom recommends using one of the following modems: Ven-Tel
2400, Hayes 2400 Smartmodem, or Maxwell 2400 VP.
7.
If you plan to download over the Chain Port, verify that all Chain Port
connectors are installed as described in the Access-T operation manual.
ACST-6351-001
Larscom Access-T 100, 200, 400, & 1500 Network Access DSU/CSU
October 1996
Software Downloading Instructions
3