Alarm History
The Alarm History report (
ALARMS—ALARM HISTORY
) displays the status and
occurrences of up to 23 Access-T alarms. Access-T can provide up to four
separate alarm histories: DTE, LINE, AUX PORT, and CHASSIS. The following
information is displayed for each of the alarm conditions.
•
The date and time of the alarm’s first change of state.
•
The date and time of the alarm’s last (most recent) change of state.
•
The initial status (at the most recent system startup or clearing).
•
The current status.
•
A count of the times the alarm has changed state.
Figure 7-1 illustrates an example of the Line Alarm History display.
To view an alarm history report, follow these steps:
1.
Select
ALARMS
from the Main Menu Line.
2.
Select
ALARM HISTORY
.
3.
Select the specific history you wish to view (
DTE
,
LINE
,
AUX PORT
, or
CHASSIS
). The alarm history report appears on the screen.
4.
Press the
Esc
key to exit the display.
Clearing the Alarm History
The alarm history can be cleared in two ways. To clear the entire alarm history,
use the
ALARMS—CLEAR HISTORY—FORCE
command; alternatively, you can clear
only the viewed alarms via the
ALARMS—CLEAR HISTORY—VIEWED
command. Both
commands will clear the CP Poll History, too. When either of the
ALARMS—CLEAR
HISTORY
commands is issued, the following occurs.
•
The
ALERT
indication is removed from the Menu Window. (When
using the
VIEWED
option, the indicator is cleared only if all current
alarms at the master and slave have been previously viewed and
cleared).
•
Each alarm history display (
DTE
,
LINE
,
AUX PORT
, and
CHASSIS
) will have
zeros in the time and count fields, and the initial and current states
will be the state at the time of clearing.
ACST-0351-005
Chapter 7
June 1996
Alarms, Reports, and Tests