MENU PATH
OPTIONS / RESULTS
ALARMS
→
SETUP
→
DTE
→
ALARM TYPE
✝
→
ENABLE
ALARMS
→
SETUP
→
DTE
→
ALARM TYPE
✝
→
DIAL
ALARMS
→
SETUP
→
LINE
→
ALARM TYPE
✝
→
ENABLE
ALARMS
→
SETUP
→
LINE
→
ALARM TYPE
✝
→
DIAL
ALARMS
→
SETUP
→
AUX
→
ALARM TYPE
✝
→
ENABLE
ALARMS
→
SETUP
→
AUX
→
ALARM TYPE
✝
→
DIAL
ALARMS
→
SETUP
→
CHASSIS
→
ALARM TYPE
✝
→
EN-
ABLE
ALARMS
→
SETUP
→
CHASSIS
→
ALARM TYPE
✝
→
DIAL
NO, YES
NO, YES
NO, YES
NO, YES
NO, YES
NO, YES
NO, YES
NO, YES
ALARMS
→
THRESHOLD
→
LINE
→
BPV
ALARMS
→
THRESHOLD
→
LINE
→
ES INTERVAL
ALARMS
→
THRESHOLD
→
LINE
→
ES ERRORS
5 - 9 (negative exponent of BPV
rate)
1 - 15 minutes, default is 6
1 to 399 errors, default is 100
ALARMS
→
THRESHOLD
→
AUX PORT
→
BPV
ALARMS
→
THRESHOLD
→
AUX PORT
→
ES INTERVAL
ALARMS
→
THRESHOLD
→
AUX PORT
→
ES ERRORS
5 - 9 (negative exponent of BPV
rate)
1 - 15 minutes, default is 6
1 to 399 errors, 100 is default
ALARMS
→
NODE ALARM STATUS
Display showing which nodes are
in a state of alert
ALARMS
→
ALARM HISTORY
→
DTE
ALARMS
→
ALARM HISTORY
→
LINE
ALARMS
→
ALARM HISTORY
→
AUX PORT
ALARMS
→
ALARM HISTORY
→
CHASSIS
Local alarm history display
Local alarm history display
Local alarm history display
Local alarm history display
ALARMS
→
CP POLL HISTORY
→
1-15 (16-30)
Polling history for nodes 1-15 (16-30)
LINE
→
FRAMING
LINE
→
CODING
LINE
→
LINE BUILD OUT
LINE
→
T1.403
LINE
→
YELLOW
LINE
→
DATA LINK ID
LINE
→
INBAND
D4, ESF
AMI, B8ZS
0, -7.5, -15 dB
OFF, ON
OFF, ON
CSU, DTE
ON, OFF
DTE
→
PORT1 (2, 3, 4)
→
RATE
DTE
→
PORT1 (2, 3, 4)
→
CLOCK
DTE
→
PORT1 (2, 3, 4)
→
DATA
DTE
→
PORT1 (2, 3, 4)
→
INTERFACE
DTE
→
PORT1 (2, 3, 4)
→
RTS
DTE
→
PORT1 (2, 3, 4)
→
TTM
DTE
→
PORT1 (2, 3, 4)
→
BIT 7
Nx64,Nx56
NORMAL, INVERTED
NORMAL, INVERTED
RS449, V.35
ACTIVE, PERMANENT
OFF, ON
OFF, ON
Table 5-B. Access-T Menus, Parameters, and Options (cont’d)
Chapter 5
ACST-0351-005
The Terminal Interface
June 1996
5-10