Maintenance
9
The Access-T DSU/CSU is not field-repairable. It should be returned to Larscom
Incorporated for any required repairs. Preventive maintenance is not required
for the Access-T.
Replacing the Fuse
Access-T Series 100, 200, and 400 Units, AC Power
Access-T 100, 200, and 400 units powered by an ac source come equipped with
a spare fuse to be used in the event that the primary fuse blows. The spare fuse
is stored behind the rear panel, inside a small plastic casing. To remove the
blown fuse and install the spare fuse, follow these steps:
1.
Turn off power and remove the power cord from the rear of the
Access-T 100, 200 or 400 unit.
2.
Use a small, flathead screwdriver to remove the fuse assembly from
the rear of the unit. Insert the screwdriver head into the notch
(location A in Figure 10-1) and pry the fuse assembly (B) out. Be
careful to fit the screwdriver head firmly in place before prying the
assembly out, or the plastic could chip.
3.
Remove the blown fuse (marked C in Figure 9-1) from the casing.
4.
Using the screwdriver head, push the top of the rectangular section
of the fuse assembly (marked D in Figure 9-1). A small box will
protrude from the bottom of the assembly.
5.
Remove this smaller box from the assembly.
ACST-0351-005
Chapter 9
June 1996
Maintenance
9-1