13.
Select
INACTIVITY TIMEOUT
.
14.
Enter the Inactivity Timeout value. (The Inactivity Timeout is the
length of time, in minutes, that Access-T waits before hanging up an
inactive line. Inactivity is defined as no characters received by the
Access-T.) Acceptable timeout values range from 1 to 255 minutes;
an entry of 0 (zero) disables the Inactivity Timeout function. Termi-
nate the entry by pressing the
Enter
key. Press the
Esc
key twice.
Note:
To minimize the time that the phone line is in
use, an Inactivity Timeout of 1 minute is recom-
mended when
UNSOLICITED=ON
.
CAUTION: If an Inactivity Timeout of 0 is speci-
fied, the dialed connection will remain in effect
until the dialed device (or modem) disconnects.
15.
Select
DIALPORT BACKOFF
.
16.
Enter the Dialport Backoff value. (This value is the time that Access-T
will wait, after Access-T disconnects from inactivity, before dialing to
report an already-reported alarm which has not been cleared. Accept-
able values range from 15 to 240 minutes.) Terminate the entry by
pressing the
Enter
key.
17.
Set the Access-T baud rate to match that of the modem. To set the
Access-T baud rate, select the
BAUD RATE
option under
SYSTEM—COM-
MUNICATION
. Also, verify that the
SYSTEM—COMMUNICATION—INTERFACE
option is set to
MODEM
.
Chapter 6
ACST-0351-005
Configuration Procedures
June 1996
6-28