To remove the blown fuse and install the new fuse, follow these steps:
1.
Turn off power and remove the power cord from the rear of the
Access-T 200 or 400 unit.
2.
Use a small, flathead screwdriver to remove the fuse assembly (la-
beled
F1
on the rear panel).
3.
Remove the blown fuse from the casing.
4.
Insert a new fuse where you removed the blown fuse in step 3.
Access-T 1500
Both the ac and dc power supplies for the Access-T 1500 chassis have fuses
which can be replaced. AC power supplies employ a 5 A, 250 V fast-blo fuse; dc
power supplies employ a 7 A, 125 V fast-blo fuse.
To remove the blown fuse and install the new fuse, follow these steps:
1.
Remove the power supply as follows:
a.
Remove the faceplate covering the power supplies by loosening
the thumbscrews at the top of the faceplate. Then, grasp the
extractor handle at the bottom of the faceplate an pull.
b.
Remove the defective power supply by pulling on the handle.
2.
Remove the blown fuse from the power supply board.
3.
Insert a new fuse where you removed the blown fuse in step 2.
4.
Re-insert the power supply by carefully aligning the power supply
in the guiding card slots. Be sure the card is oriented so that the plug
on the rear of the power supply mates with the connector in the
chassis. Verify that the power supply is securely mated to the rear of
the chassis.
Replacement Parts
Field-replaceable parts are limited to the various cables and the fuse. When
ordering spare or replacement parts, use the model/part numbers given in
Table 9-A. Contact Larscom Customer Service Administrators for any other
information required.
ACST-0351-005
Chapter 9
June 1996
Maintenance
9-3