Figure 7-1. Alarm History Display
Access-T will dial out to report an alarm again if the Alarm History is not
cleared within the specified Dialport Backoff time. (The Dialport Backoff time
can range from 15 to 240 minutes, as described in Chapter 6 under the
heading Setting Modem Dialout.) To prevent repeated dialouts of the same
alarm, clear the Alarm History before the Dialport Backoff period elapses.
To clear the alarm history of viewed alarms, perform the following steps:
1.
Select
ALARMS
from the Main Menu Line.
2.
Select
CLEAR HISTORY
.
3.
Select
VIEWED
or
FORCE
.
4.
Select
YES
or
NO
.
5.
Press the
Enter
key.
6. Press the
Esc
key to return to the Main Menu Line.
Special procedures must be followed when handling alarms at a master Access-T.
For a detailed explanation of how to view and clear alarms on a master unit,
refer to Chapter 8.
— USER LINE ALARM HISTORY
date and time
Type
First
Last
Initial Current Count
BPVS
date-time date-time NORMAL
ALARM
3
YELLOW
date-time date-time NORMAL
NORMAL
6
AIS
date-time date-time NORMAL
ALARM
9
USS
date-time date-time NORMAL
ALARM
1
SIGNAL LOSS
date-time date-time NORMAL
DISABLED
0
SYNC LOSS
date-time date-time NORMAL
DISABLED
0
ES
date-time date-time NORMAL
DISABLED
0
LOOP
date-time date-time NORMAL
NORMAL
4
Press EXIT Key to Continue.
Chapter 7
ACST-0351-005
Alarms, Reports, and Tests
June 1996
7-6