57
If the connections to the terminal strip X5 between 1 and 2 and the connection to terminal strip X1.3 are open,
the motor coasts to stop. It appears in the display
. After reconnecting the TSG door operator restarts in
normal mode.
Both signals must reach the same state at enable or disable within 0,5[seconds]. If this does not happen or X5
or X1.3 are severed, there will be an error message, the display
flashes and the message of TSG OK
disappears. To correct the error, first the circuit needs to be corrected, and then the circuit turns off and again
turns on.
NOTE:
To activate the function, the parameter must be set according to h3 (see Table 12: h-parameter
/ page 38).
12.4 Leading limit switch
The relay outputs for “Door is open”, “Door is closed” (plug X2) can be set leading. According to the configu-
ration the limit switch switches before the end position is reached.
Table 16: adjusting parameter h2
adjusting
parameter
h2
Leading
„Door is
opened“
[cm]
Leading
„Door is
closed“
[cm]
adjusting
parameter
h2
Leading
„Door is
opened“
[cm]
Leading
„Door is
closed“
[cm]
00
0
0
16
3
3
01
0
0
17
5
0
02
0
1
18
10
0
03
1
0
19
15
0
04
1
1
20
0
5
05
0
2
21
5
5
06
2
0
22
10
5
07
1
2
23
15
5
08
2
1
24
0
10
09
2
2
25
5
10
10
0
3
26
10
10
11
3
0
27
15
10
12
1
3
28
0
15
13
3
1
29
5
15
14
2
3
30
10
15
15
3
2
31
15
15
Summary of Contents for TSG V4
Page 1: ...1 Installation and Operating Instructions for the device series Door Operator TSG V4...
Page 82: ...82...
Page 83: ...83...