28
CAUTION:
If any mechanical adjustment is performed after the self-learn procedure (example tightening
the TSG toothed belt or readjusting the end stops or buffer stops) this will affect the saved
values of the door measurements. A new self-learn procedure must be carried out every time a
mechanical adjustment has been made!
CAUTION:
If the function stop input two channel is switched on (h3=04), the connector X1 must be com-
pletely wired when initial self-learn procedure, so that the stop channel is present.
NOTE:
Saved parameters are not reset to default values after a self-learn procedure! Parameter EE
is used to reset parameters to their default values (see also Table 13: E parameter / page 43).
7.5 Enter the weight to be traversed
By selecting the parameter P9 the total weight can be read and adjusted.
7.5.1 Press briefly of the jog wheel
The display shows the adjusted total weight. It can’t be changed. Another quick press on the jog wheel, the
display returns to parameter P9.
7.5.2 Press long of the jog wheel
Press the jog wheel and hold it for about 5 [seconds] you will start with the self-learn procedure (see also cap.
7.4 Self-Learn Procedure / page 27). First, the currently adjusted total weight is flashing in the display. The
executive personnel must enter the actual total weight of the components to be traversed (door panel, protec-
tive device,).
Table 8: Weight Input
Assignment of the input of actual existing total weight
01
10[kg]
02
20[kg]
:
:
40
400[kg]
Summary of Contents for TSG V4
Page 1: ...1 Installation and Operating Instructions for the device series Door Operator TSG V4...
Page 82: ...82...