24
7 Electrical settings and commissioning
7.1 Display
The TSG electronic unit has a two-digit 7-segment display to indicate the current state and show the menu
with parameters and their corresponding values.
Table 7: TSG display
Display
Meaning
There is no activation.
The TSG is not calibrated. Manual calibration must be per-
formed.
If the TSG electronics detects an incorrect motor or an in-
correct motor connection, the display flashes and no cali-
bration is possible.
(see also cap. 7.4 Self-Learn Procedure / page 27).
Open signal is present (
Op
en).
Close signal is present (
Cl
ose).
Door is opened (
O
pene
d
).
Door is closed (
C
lose
d
).
Door is obstructed (
bl
ocked).
Intermediate position reached
(see also cap. 18.2 Intermediate positions in the travel zone
/ page 79)
Reversing range reached
(Parameter bd, see also Table 11: b parameters / page 36)
Triggering light curtain (Light Curtain)
(see also section 18.4 Light Curtain Kit / page 81)
Stop function (see also section 12.3 Stop input / page 54)