51
11 Setting for force limiting
The maximum speed limit, force and energy are to be checked and recorded at the closing and shearing edges
after commissioning or changing of parameters at the door by the executive personnel.
11.1 Maximum kinetic energy
According to the relevant standards, the maximum kinetic energy W
kin
to the closing and shear edges 10[J]
must not be exceeded. This requires to know the actual total weight of the components to be traversed (door
panel, protective device,…) and be entered before start the self-learn (see also cap. 7.4 Self-Learn Procedure
/ page 27).
The maximum speed to be set is calculated with:
when:
v:
maximum allowed speed [m/s],
W
kin
:
kinetic energy [J],
m:
mass [kg].
11.2 Maximum static force
According to the relevant standards, the maximum static force F to the closing and shear edges 150[N] must
not be exceeded.
The parameter P8 (or parameters b2 / b7) represents the value for the maximum allowable static force. By
increasing the value of P8 (or b2 or b7), this allowable static force will increase.