11
Section 1: Operator Controls
7/30/12
ZSR54 & ZSR60 Accu-Z Razor
®
Zero Turn Mowers 357-388SM
Table of Contents
Figure 1-22
Figure 1-23
Figure 1-24
33685
33696
33697
Control Panel Removal
Refer to Figure 1-22:
1.
Chock wheels to secure mower and prevent
movement while repairs are made.
2.
Disconnect battery to prevent accidental shock. See
“Battery Assembly Removal” on page 22.
3.
Disconnect and remove seat for easy access.
4.
Cut and remove plastic zip ties securing the throttle
and choke cables to the frame.
Refer to Figure 1-23:
5.
Loosen engine clamps on both the throttle and choke
cables. Mark each cable for reference.
6.
Disconnect the throttle and choke cables from the
engine.
Refer to Figure 1-24:
7.
Loosen and remove the cross head bolts on the
control panel.
8.
Lift the control panel out of the fuel tank and
disconnect all electrical connections.
9.
While removing the control panel, insure that the
throttle and choke cable do not become bound and
pull free of the opening in the bottom of the fuel tank.
NOTE: Picture is for reference only, cable
attachments will vary with engine model and type.