3.7 CHECK/ADJUST RATIOS
A. To check and/or adjust the ratio separately, measure
the amount of water and finished product dispensed
into a graduate cylinder. Adjust the finished product to
equal the volume of water dispensed. To do this:
• Turn keyswitch to
(FLUSH)
.
• Press the and
#
buttons on outside edge of
door panel at the same time to access the Ratio Mode.
B. Press and release the
PUSH
button. Water will pour
automatically. use a 500 ml graduate cylinder to collect
dispensed water. Note level of water. 450 ml should pour
into cylinder. Each band is 5 ml. If off more than two
bands, troubleshoot water sub-system. Discard water
sample.
C. Replace cylinder under nozzle and press
PUSH
.
Discard first sample. Finished product will dispense.
Discard finished product.
D. Replace cylinder under nozzle and press
PUSH
.
Finished product will dispense - the target is the same
as “water only” level in that was measured in Step B.
If within 5 ml, return to operation.
E. If finished product volume does not qual water volume,
adjust the ratio by pushing and
#
buttons.
• Press
PUSH
and check volume again.
• Repeat until correct.
For
example:
• If the ratio is four bands below, toggle down to -4
using the and
#
buttons.
If the ratio is three bands above water level, toggle
up to +3. Press
PUSH
and check volume again.
When the volume of finished product matches the
water level, turn key to
(ON)
position to return
dispenser to service.
3.8 DISPENSING CONFIGURATIONS
The dispenser has two different dispensing configurations,
depending on the model. These configurations are:
PUSH and HOLD
The touch sensor switch is pressed to start dispensing and
released to stop dispense.
• Place a vessel on the target located on the cup rest.
• Press and hold the
PUSH
(on select models)button to start
the flow of product.
• Release the pressure on the button to stop the flow of product.
Hidden Ratio
Check/Adjust
Buttons
POUR / CANCEL
17