6.15 WATER CALIBRATIONS VALVE/FLOW WASHER REMOVAL/ REPLACEMENT
A. Remove the concentrate product.
B. Turn key to
(OFF).
C. Remove nozzle from the water fitting and concentrate delivery tube.
D. Remove the platform base(s).
E. Remove the screws that secure the pump assembly platform base to the cabinet.
F. Tilt the pump assembly platform base forward.
G. Disconnect waterproof connectors on solenoid and flowmeter.
H. Slide the two retainers on the top and bottom of the water calibrations valve assembly to the
“disengage” position.
I. Push the water calibrations valve assembly down until the outlet connector tube telescopes into
the base of the unit.
J. While holding the outlet connector tube, lift up on the water calibrations valve assembly to
disengage it from the outlet connector tube.
K. Remove the water calibrations valve assembly, being careful not to lose the flow washer that is
fitted in the top end of the outlet connector tube.
L. Replacement is as follows:
• Place the flow washer in the end of the connector tube, being careful to place the concave
side of the flow washer down.
• Position the outlet end of the water calibrations valve assembly on the outlet connector
tube and fasten secure, by sliding the retainer on the water calibrations valve assembly to
the locked position.
• Lift up on the water calibrations valve assembly to withdraw the outlet connector tube from
the base of the dispenser, and fit the assembly to the manifold outlet.
• Secure the water calibrations valve assembly to the manifold outlet by sliding the retainer to
the locked position.
• Replacement is the reverse of removal.
6.16 NOZZLE REMOVAL/REPLACEMENT
A. Remove nozzle from water fitting and concentrate delivery tube.
B. Install the nozzle in the dispenser, use caution to avoid damaging the o-ring.
6.17 ELECTRONICS REMOVAL/REPLACEMENT
When removing or replacing control box power supply, electronic board, refer to
STEP 6.13 K
to
calibrate
SOLD OUT
feature.
F
WARNING
DISCONNECT POWER BEFORE REMOVING POWER BOX.
ADVERTENCIA
DESCONECTE LA ALIMENTACIÓN ANTES DE RETIRAR LA CAJA DE ALIMENTACIÓN.
AVERTISSEMENT
DÉBRANCHEZ L’ÉLECTRICITÉ AVANT LE DÉMONTAGE DE LA BOÎTE ÉLECTRIQUE AINSI
QUE POUR L’ENLÈVEMENT DES CIRCUITS ÉLECTRONIQUES.
2-Valve Control Box Removal/Replacement
A. Remove drip tray, splash plate and thumb screw.
B. Disconnect power cord.
C. Lift control box of studs and remove.
D. Replacement is the reverse of removal.