15
. ELECTRICAL EQUIPMENT
15-12
SUPER8 50 2T
STARTER RELAY INSPECTION
Remove the foot-floor cover.
Disconnect the starter relay coupler and
then remove the starter relay.
Connect the starter relay (D) terminal to the
12V battery positive (+) terminal and the
relay (C) terminal to the battery negative (-)
terminal. Check for continuity between
the starter relay (A) and (B) terminals.
The relay is normal if there is continuity.
STARTER MOTOR REMOVAL
Disconnect the starter motor cable.
Remove the two bolts attaching the starter
motor and remove the starter motor.
The installation sequence is the reverse of
removal.
Starter Relay
Starter Motor
Bolts