KW Aufzugstechnik GmbH OPERATING MANUAL DAVID-613
DAVID-D613-V125-E 13.04.2021
Page - 87 -
Parameter: Dangerous goods transport via key switch in the landing panel with ma-
nuel door closing & opening – option 1
Activation via parameter setting: ON-1
The functional sequence is as follows:
1. On the corresponding floor, the elevator is brought in by preference.
2. The special trip is triggered by the "Dangerous goods transport" key switch (E522) on the out-
side panel by briefly pressing the key switch.
3. The elevator goes up to the floor and the door opens. The elevator is now in the "dangerous
goods transport" mode. "SPECIAL JOURNEY" is displayed. The door can only be controlled man-
ually using the door OPEN button (E518..E521).
4. An internal call to the target floor must be pressed. This car call can be corrected by pressing
again on another target floor.
5. Now the door must be closed manually using the door CLOSE button (E519). When the door is
closed, the elevator moves to the target floor.
6. There is the elevator with the door closed. The door must now be opened manually using the
door OPEN button (E518..E521).
7. Now the "Dangerous goods transport" mode can be ended by an impulse on the "Dangerous
goods transport" key switch (E522) in the interior panel or another dangerous goods transport can
be carried out.
Parameter: Dangerous goods transport via key switch in the car panel with manuel
door closing & opening – option 2
Activation via parameter setting: ON-1
The functional sequence is as follows:
1. The elevator is called via the normal call button or key switch in the outer panel of the special travel
control.
2. The special trip is triggered by the "Dangerous goods transport" key switch (E522) in the interior
panel of the car by briefly pressing the key switch.
3. An optical display follows as confirmation of activation (display in the outside panel). The elevator is
available exclusively for this transport (external calls to the elevator system and the automatic door
closing functions are switched off).
4. The elevator can then be loaded with the dangerous goods.
5. The elevator door closes by pressing the "Door to" button in the outside call panel of the special
travel control of the loading stop. The button must be pressed until the door is completely closed - vis-
ual acknowledgment by lighting up the acknowledgment ring on the "door closed" button.
6. The operator goes to the destination stop. The "Dangerous goods transport" key switch in the exter-
nal call panel is operated at the destination stop. Only now the elevator moves to the target floor and
opens the door automatically after reaching it.
7. The elevator can be unloaded.
8. By closing the key switch in the car panel, the special journey is ended and the elevator is available
again for normal use.
Parameter: Dangerous goods transport via key switch in the landing panel with auto-
matic door control – option 3
Activation via parameter setting: ON-2
The functional sequence is as follows:
1. The elevator is fetched on the corresponding floor using the key switch outside preference.
The elevator goes up to the floor and the door opens. The elevator is now in the "dangerous goods
transport" mode. "SPECIAL JOURNEY" is displayed.
2. The cabin is loaded and the door remains open. There are no internal calls or outside calls possible.
The door can only be closed by another impulse at the preferred switch on the same floor.
3. Now the elevator can be picked up again on the target floor by outside preference.
4. The door then opens on the target floor and the elevator can be unloaded.
5. After an adjustable time (B24 parameter time call input), the elevator system returns to normal oper-
ation or can be activated by another key switch impulse on the outside.
6. Optionally, in menu B24 the option "B24 forced recovery individually" or "B24 forced recovery indi-
vidually after emptying" can be selected.
Summary of Contents for DAVID 613
Page 1: ...OPERATING MANUAL LIFT CONTROLLER SYSTEM DAVID 613 FUNCTIONS START UP INSTRUCTIONS...
Page 2: ...KW Aufzugstechnik GmbH OPERATING MANUAL DAVID 613 DAVID D613 V125 E 13 04 2021 Page 2...
Page 10: ...KW Aufzugstechnik GmbH OPERATING MANUAL DAVID 613 DAVID D613 V125 E 13 04 2021 Page 10...
Page 12: ...KW Aufzugstechnik GmbH OPERATING MANUAL DAVID 613 DAVID D613 V125 E 13 04 2021 Page 12...
Page 13: ...KW Aufzugstechnik GmbH OPERATING MANUAL DAVID 613 DAVID D613 V125 E 13 04 2021 Page 13...
Page 14: ...KW Aufzugstechnik GmbH OPERATING MANUAL DAVID 613 DAVID D613 V125 E 13 04 2021 Page 14...
Page 34: ...KW Aufzugstechnik GmbH OPERATING MANUAL DAVID 613 DAVID D613 V125 E 13 04 2021 Page 34...
Page 35: ...KW Aufzugstechnik GmbH OPERATING MANUAL DAVID 613 DAVID D613 V125 E 13 04 2021 Page 35...
Page 98: ...KW Aufzugstechnik GmbH OPERATING MANUAL DAVID 613 DAVID D613 V125 E 13 04 2021 Page 98...