D5 Energy counter
The energy counter is implemented in submenu D5. There are two energy meters available for the
supply of energy as well as for energy recovery:
Display of the energy purchase
Erasable, display of the related energy
Display of energy recovery
Erasable, display oft he supplied energy
Delate energy meter?
No - Yes
Energy reference number of pulse per KWh
000x pulses / KWh
Energy recovery pulse number per KWh
000x pulses / KWh
D6 Environmental conditions
In the submenu D6 parameters of the environmental conditions are displayed:
Temperature ZR currently
Temperature in degrees celsius
Temperature ZR max
Temperature in degrees celsius
Temperature ZR min
Temperature in degrees celsius
Temperature FKR currently
Temperature in degrees celsius
Temperature FKR max
Temperature in degrees celsius
Temperature FKRf min
Temperature in degrees celsius
Temperature control cabinet currently
Temperature in degrees celsius
Temperature control cabinet max
Temperature in degrees celsius
Temperature control cabinet min
Temperature in degrees celsius
Temperature pit-brow currently
Temperature in degrees celsius
Temperature pit-brow max
Temperature in degrees celsius
Temperature pit-brow min
Temperature in degrees celsius
Temperature shaft pit currently
Temperature in degrees celsius
Temperature shaft pit max
Temperature in degrees celsius
Temperature shaft pit min
Temperature in degrees celsius
Humidity control cabinet currenlyt
From 20% to 80%
Humidity control cabinet max
From 20% to 80%
Humidity control cabinet min
From 20% to 80%
Humidity pit-brow currently
From 20% to 80%
Humidity pit-brow max
From 20% to 80%
Humidity pit-brow min
From 20% to 80%
Humidity shaft pit currently
From 20% to 80%
Humidity shaft pit max
From 20% to 80%
Humidity shaft pit min
From 20% to 80%
For resetting with a button of the resettable counter functions there are input functions:
Exxx - Reset journey counter
Exxx - Reset journey counter up
Exxx - Reset journey counter down
Exxx - Reset Floor crossing counter
Exxx - Reset operating- hours meter
Exxx - Reset Failure hour counter
Exxx - Reset malfunction counter
Exxx - Reset motor hour meter
Exxx - Reset Door movement counters
Exxx - Reset Energy meters
Summary of Contents for DAVID 613
Page 1: ...OPERATING MANUAL LIFT CONTROLLER SYSTEM DAVID 613 FUNCTIONS START UP INSTRUCTIONS...
Page 2: ...KW Aufzugstechnik GmbH OPERATING MANUAL DAVID 613 DAVID D613 V125 E 13 04 2021 Page 2...
Page 10: ...KW Aufzugstechnik GmbH OPERATING MANUAL DAVID 613 DAVID D613 V125 E 13 04 2021 Page 10...
Page 12: ...KW Aufzugstechnik GmbH OPERATING MANUAL DAVID 613 DAVID D613 V125 E 13 04 2021 Page 12...
Page 13: ...KW Aufzugstechnik GmbH OPERATING MANUAL DAVID 613 DAVID D613 V125 E 13 04 2021 Page 13...
Page 14: ...KW Aufzugstechnik GmbH OPERATING MANUAL DAVID 613 DAVID D613 V125 E 13 04 2021 Page 14...
Page 34: ...KW Aufzugstechnik GmbH OPERATING MANUAL DAVID 613 DAVID D613 V125 E 13 04 2021 Page 34...
Page 35: ...KW Aufzugstechnik GmbH OPERATING MANUAL DAVID 613 DAVID D613 V125 E 13 04 2021 Page 35...
Page 98: ...KW Aufzugstechnik GmbH OPERATING MANUAL DAVID 613 DAVID D613 V125 E 13 04 2021 Page 98...