Specifications
This guide for use by qualified personnel only.
NOTE
: All charging specifications are at nominal conditions: ambient temperature of 77 °F (25 °C), 120 VAC, 60 Hz input, unless
otherwise specified.
Charger Specifications
$XWR3RZHU
$XWR3RZHU
Charging method
Three-stage charge (Bulk, Absorption, Float)
Two-stage charge (Bulk, Absorption)
The default charging method is three-stage.
Without a battery temperature sensor
Three settings with the following temperature values:
Cool 50 °F (10 °C) / Warm 77 °F (25 °C) / Hot 104 °F (40 °C)
The default setting is Warm and it can only be changed by the factory, a dealer, or a service centre.
With a battery temperature sensor (included)
The temperature compensation coefficients on a
12-volt battery are as follows:
Flooded: 27 mV × (25 °C – BTS °C)
Gel: 27 mV × (25 °C – BTS °C)
AGM: 21 mV × (25 °C – BTS °C)
The temperature compensation coefficients on a
24-volt battery are as follows:
Flooded: 54 mV × (25 °C – BTS °C)
Gel: 54 mV × (25 °C – BTS °C)
AGM: 42 mV × (25 °C – BTS °C)
Output current (maximum)
100 ADC
150 ADC
Output voltage
12 VDC
12 VDC
Output voltage range
5–16 VDC
5–16 VDC
Equalization cycle
Automatic, Manual by
.
anbus SCP
Automatic, Manual by
.
anbus SCP
Optimal charging efficiency
> 85%
> 85%
AC input power factor (at full charge rate)
> 0.98
> 0.95
AC input current
24A max. (including pass-thru)
24A max. (including pass-thru)
AC input voltage
120 VAC
120 VAC
AC input voltage range
85–140 VAC
85–140 VAC
Dead battery charge voltage
> 5 VDC
> 5 VDC
Supported AC input types
Single input (up to 30 amps)
Split phase (up to 30 amps per line)
Dual input (up to 30 amps per line)