Installing the Inverter/Charger
When making the AC input and AC output connections,
observe the correct color code for the appropriate AC wire, as
described in Table 2 on page 1
3
.
To make the AC input connections:
1. Locate the wiring compartment cover panel and remove
the four screws.
2. Remove the cover panel from the unit to access the wiring
compartment.
3. Remove one of the AC knockouts from the front or side
of the unit. Do not leave the knockout inside the wiring
compartment.
4. Install a strain-relief clamp in the AC knockout.
5. Run the AC wiring through the strain-relief clamp.
Strip approximately 2 inches (50 mm) off the jacket from
the AC cable and separate the wires.
Using a 1/4" blade slot screwdriver, loosen the terminal
screws on the terminals. Do not remove the screws.
Connect the line and neutral wires to the input terminals
(labeled AC Input on the terminal block, Figure 7 on page
2
8
).
$XWR3RZHU
:
Connect Line 1 to
L1
, Neutral to
N
, Line 2 to
L2
.
$XWR3RZHU
:
Connect Line to
L
, Neutral to
N
, Ground to
G
.
Tighten the terminal screws. Leave some slack wire
inside the wiring box.
Connect the ground wires to a free position on the ground
bus, Figure 7 on page 29. If solid ground wire is being
used, the wire can be connected directly under the screw
heads. If stranded ground wire is being used, ring
terminals must also be used.
Secure the strain-relief clamp on the AC input cable
jacket.
EQUIPMENT DAMAGE
Connect wires to the correct terminals in the terminal block that is split into
INPUT and OUTPUT sections. Damage may occur if the unit is wired
incorrectly to the wrong terminals.
Do not remove or loosen factory installed wiring.
Failure to follow these instructions can damage the unit and/or damage
other equipment.