-209-
3.15 Multi Ring Status
Status
Description
Group #
Ring entities
Ring Status
Status:
[
STANDBY
] - The ring is normal and with no failure. The backup link is under
standby and not activated.
[
BACKUP
] - Failure occurred somewhere on the ring and the master has activated the
backup link to support continuous operation of the ring. The ring failure should be
repaired immediately by the persons who are in charge.
[
Master Failed
] - Possible failure occurred on the master unit itself. No backup
support is available. This is a critical situation and should be repaired immediately.
[
Backup Port Failed
] - Possible failure occurred on the backup link. No backup
support is available. This is a critical situation and should be repaired immediately.
Members
The number of the switch members in the ring. Click to browse the ring member
information and status. This is a helpful tool for diagnosing where the ring failure is
located.
Ring ID
The group ID assigned to the ring
Local Port Status
Port #
Port number of this switch
Link Status
Port link status (Refer to the section of Port Configuration.)