-152-
2.22 OPA (Optical Power Alarm) Configuration
OPA function allows to set lower and upper alarm thresholds for the optical power of the fiber ports. The alarm
is sent via relay alarm output and SNMP trap. The optical power is monitored once every second. Note that if
no SFP transceiver is installed or no DDM is supported in the SFP transceiver, OPA function is dsiabled
automatically.
_____________________________________________________________________________________________________________________________ ______________________
Configuration
Description
729BU
___________________________________________________________________________________________________________________________________________________
Port
The fiber optical port number
MinMode
enable alarm if power is less than the lower threshold
MinLimit
set lower threshold limit, unit dBm
ManMode
enable alarm if power is higher than the upper threshold
ManLimit
set upper threshold limit, unit dBm
730BU
Save
Click to save the changes.
Reset
Click to undo any changes made locally and revert to previously saved values.
_____________________________________________________________________________________________________________________________ ______________________
Note:
The alarm can be via relay alarm output and SNP trap. The alarm via SNMP trap can be disabled. Refer to
Configuration > Security > Switch > SNMP > System
page for SNMP Trap Configuration.
Summary of Contents for KGS-1064-HP
Page 1: ... 1 KGS 1064 HP Web Management Interface User s Manual Software Rev 1 0 or up DOC 170505 ...
Page 10: ... 10 5 4 Configuration 219 5 4 1 Save 219 5 4 2 Upload 220 Glossary 221 ...
Page 135: ... 135 2 17 7 DSCP Based QoS ...
Page 136: ... 136 ...
Page 138: ... 138 2 17 8 DSCP Translation ...
Page 139: ... 139 ...